Home Email Site index


Solvent Recovery

SRS-175 XPM

Description

The solvent recovery unit SRS-175 XPM has a tank capacity of 66 litres (17.5 US gallons) and a distillation rate of approximately 11 litres (3 US gallons) per hour. The unit operates on 220 Volts at 60 cycles (50 optional) and consumes 12.5 amps.

How does it work

Dirty solvent is added to the teflon-lined tank, and the stainless steel lid is replaced and clamped down. As the temperature raises above the boiling point of the solvent being recovered, the solvent vaporizes into a gaseous state through the insulated exhaust tube into the air-cooled condenser where it is condensed into a reusable solvent. The remaining solids in the still bottom can then be removed for disposal and the system is ready to process the next batch.

Characteristics

  

Tank volume US gal. / (litres) 20 (76)
Tank capacity US gal. / (litres) 17.5 (66)
Approximate recovery rate US gal. / (litres) per hour 3 (11)**
*May differ according to products and % of residue.

  • Teflon-coated tank
  • Electrically heated, may reach 500º F (260 ºC)
  • Air-cooled
  • De-Sta-C0 lid clamping system
  • Explosion proof electrical Class 1, Division 1
  • Temperature controlled electronically
  • CSA approved certified to UL standard 2208
  • Liner bags available
  • Solvent-resistant external finish
  • Optional : Stainless steel tank & condenser
  • Optional : Vacuum system, water separator, auto-fill system, etc...

Electrical Features

NEMA 7 XP Explosion Proof Class 1, Division 1
Voltage   220
Cycle   60 (50 optional)
Amperage   12.5
Power   3 Kw / h

Dimensions

Width in. (cm)   24 (61)
Height in. (cm)   60 (152)
Length in. (cm)   40 (102)
Weight lbs. (Kg)   200 (91)

Realization : www.webtelecom.ca Copyright 2007 © SRS Environment inc.